CT-1000
1000 A DC Current Transducer (DCCT)
±1000 A Full-Scale high precision DCCT based on the 0-FLUCS technology available in the current-output or voltage-output version
- Overview
- Features
- Technical specifications
- Ordering options
- Documentation
- Software/Firmware
Overview
Accurate and precise monitoring of DC and AC currents with high bandwidth, low noise and negligible drift.
The 0-FLUCS (0-FLUx Current Sensor) current transducer family is based on a closed loop technology that allows reaching best-in-class performance for a variety of applications.
The CT-1000 transducers are rated at a at maximum bipolar primary current of 1000A with a transform ratio of 1:2000.
Galvanic isolation between the primary and the secondary circuits allows to measure currents at a different potential and simplifies interfacing when using the 0-FLUCS as the feedback element of current regulated power supplies.
Output from the CT-1000 transducers can be chosen between two different versions: secondary current output or buffered voltage output (low temperature coefficient shunt resistor and low-noise amplifier are embedded in the device).
Main characteristics of the 0-FLUCS current transformers are negligible temperature coefficient on the secondary output current, excellent linearity and extremely low noise.
DC current transformers represents the ideal replacement for systems where Hall-effect sensors are used as current sensing elements and better performances are needed.
0-FLUCS exclusive technology allows the user to obtain performances which cannot be reached with other current sensing techniques.
Want to get more into this topic? Just click the following link:
0-FLUCS Exclusive Technology – An Overview
Ideal for EV, battery testing, current calibration, AC mains monitoring and precision power supplies.
Main application fields for these current transducers are all the ones where the accuracy and precision of the current measurement is critical:
- battery testing and characterization (EV);
- calibration setups;
- test stands;
- precise AC mains monitoring;
- extremely stable regulated power supplies;
- power inverters.
Due to the excellent characteristics, the CT-1000 transducers can be used in a variety of calibration, acceptance testing and quality control applications in industrial, power generation and automotive fields.
Commercially available versions of the CT-1000 current transformers are the current-output CT-1000 and the respective voltage-output version CT-1000V. A LED indicating the correct operation of the device is present on all versions.
Combine it with the low-noise PS1215 for optimal performance or use the CT-BOX-1000!
The CT-1000 can be used with the dedicated PS1215 low-noise AC-DC power supply available in two different versions differing by their cablings: take a look at versions dedicated to the current-output and the voltage-output current transducer series on the PS1215 product page.
For a complete measurement solution, the CT-1000 is part of the CT-BOX-1000 system, a complete solution for monitoring bipolar current up to 1000 A.
Features
- Monitoring of AC and DC currents
- Excellent Linearity
- Closed-loop detection
- Galvanically isolated from primary
- Low Temperature Drift
- Current-output or Voltage-output versions
- Wide bandwidth
- UL 94 V-0 flammability grade
- LED indicates correct operation
- D-sub 9 connector
- 3-year extended warranty
Technical specifications
- WCT1000VXAAA
- WCT1000XAAAA
Model
WCT1000VXAAA
WCT1000XAAAA
Maximum DC Primary Current - Ip(DC)
±1000 A
±1000 A
Current Polarity
Bipolar
Bipolar
Output Type
Voltage
Output Type
Voltage
Current
Current Transformation Ratio - N
1:2000
1:2000
Maximum DC Secondary Current - Is
-
±500 mA
External Shunt Resistor - Rs
-
0 ... 20 Ω
Small Signal Bandwidth (±3 dB) - typ. BW
> 150 kHz
> 150 kHz
Equivalent Input Noise (@BW)
< 1.5 ppm/FS @ 200Hz
< 10 ppm/FS @ 50 kHz
Specifications are guaranteed only when used with the dedicated PS1215 power supply
< 1.5 ppm/FS @ 200Hz
< 10 ppm/FS @ 50 kHz
Specifications are guaranteed only when used with the dedicated PS1215 power supply
Output Voltage
±10 V
Output Voltage
±10 V
-
Output Voltage Gain ("V"-version) - Vout/Ip
10 mV/A
Output Voltage Gain ("V"-version) - Vout/Ip
10 mV/A
-
Maximum Output Current ("V"-version)
±15 mA
Maximum Output Current ("V"-version)
±15 mA
-
Temperature Coefficient - TC
< 2 ppm/°C
Temperature Coefficient - TC
< 2 ppm/°C
< 0.5 ppm/°C
Non-Linearity
< 15 ppm
Non-Linearity
< 15 ppm
< 5 ppm
Induction into Primary (typ.)
< 25 µV (RMS)
< 25 µV (RMS)
Offset (with factory trimming)
< 10 ppm/FS
Specifications are guaranteed only when used with the dedicated PS1215 power supply
< 10 ppm/FS
Specifications are guaranteed only when used with the dedicated PS1215 power supply
Protection Signal
OK Status
OK Status
Supply Voltage (±3%)
±15 V
±15 V
Maximum Current Consumption
50 mA + Is
50 mA + Is
Secondary Coil Resistance - Rsec
25 ohm
25 ohm
Connections
D-sub 9 connector
D-sub 9 connector
Mechanical (Outer) Dimensions
107 x 91 x 50 mm
107 x 91 x 50 mm
Primary Conductor Hole Diameter - Ø
30 mm
30 mm
Operating Temperature Range
0°C ... 50°C
0°C ... 50°C
Accuracy (typical)
< 0.25% / FS
Specifications are guaranteed only when used with the dedicated PS1215 power supply
Accuracy (typical)
< 0.25% / FS
Specifications are guaranteed only when used with the dedicated PS1215 power supply
< 30 ppm / FS
Specifications are guaranteed only when used with the dedicated PS1215 power supply
Maximum Weight
600 g
600 g
Maximum DC Primary Current - Ip(DC)
±1000 A
±1000 A
Current Polarity
Bipolar
Bipolar
Output Type
Current
Output Type
Voltage
Current
Current Transformation Ratio - N
1:2000
1:2000
Maximum DC Secondary Current - Is
±500 mA
Maximum DC Secondary Current - Is
-
±500 mA
External Shunt Resistor - Rs
0 ... 20 Ω
External Shunt Resistor - Rs
-
0 ... 20 Ω
Small Signal Bandwidth (±3 dB) - typ. BW
> 150 kHz
> 150 kHz
Equivalent Input Noise (@BW)
< 1.5 ppm/FS @ 200Hz
< 10 ppm/FS @ 50 kHz
Specifications are guaranteed only when used with the dedicated PS1215 power supply
< 1.5 ppm/FS @ 200Hz
< 10 ppm/FS @ 50 kHz
Specifications are guaranteed only when used with the dedicated PS1215 power supply
Output Voltage
±10 V
-
Output Voltage Gain ("V"-version) - Vout/Ip
10 mV/A
-
Maximum Output Current ("V"-version)
±15 mA
-
Temperature Coefficient - TC
< 0.5 ppm/°C
Temperature Coefficient - TC
< 2 ppm/°C
< 0.5 ppm/°C
Non-Linearity
< 5 ppm
Non-Linearity
< 15 ppm
< 5 ppm
Induction into Primary (typ.)
< 25 µV (RMS)
< 25 µV (RMS)
Offset (with factory trimming)
< 10 ppm/FS
Specifications are guaranteed only when used with the dedicated PS1215 power supply
< 10 ppm/FS
Specifications are guaranteed only when used with the dedicated PS1215 power supply
Protection Signal
OK Status
OK Status
Supply Voltage (±3%)
±15 V
±15 V
Maximum Current Consumption
50 mA + Is
50 mA + Is
Secondary Coil Resistance - Rsec
25 ohm
25 ohm
Connections
D-sub 9 connector
D-sub 9 connector
Mechanical (Outer) Dimensions
107 x 91 x 50 mm
107 x 91 x 50 mm
Primary Conductor Hole Diameter - Ø
30 mm
30 mm
Operating Temperature Range
0°C ... 50°C
0°C ... 50°C
Accuracy (typical)
< 30 ppm / FS
Specifications are guaranteed only when used with the dedicated PS1215 power supply
Accuracy (typical)
< 0.25% / FS
Specifications are guaranteed only when used with the dedicated PS1215 power supply
< 30 ppm / FS
Specifications are guaranteed only when used with the dedicated PS1215 power supply
Maximum Weight
600 g
600 g
Documentation
Last reviewed: 2025-10-15
ⓘ More infoRevision: 3
Last reviewed: 2023-02-03
ⓘ More infoRevision: 1.2
Last reviewed: 2024-11-05
ⓘ More infoRevision: 1.1
Last reviewed: 2025-11-11
ⓘ More infoRevision: 1.2
Software/Firmware
No firmware or software available.